UV-FLOOR
GERMICIDAL UVC LED FLOOR DISINFECTOR WITH DUST ABSORBER
NO MORE HANDLING OF HAZARDOUS CHEMICALS IS REQUIRED TO STERILIZATION
WHY UV-FLOOR?
It offer high quality handheld UVC FLOOR sterilizer UV-FLOOR. The simple-to-understand effect of gravity alone will always place the floor of any healthcare property at risk of collecting harmful micro-organisms. General cleaning and vacuuming of floor surfaces may not be enough to eradicate these harmful microbes, especially with frequent foot-traffic constantly adding to the problem by continually introducing bacteria, viruses and mold from the outdoors. Studies proved that up to nine different species of bacteria were brought into healthcare facilities by the visiting public on the soles of their shoes and that bacteria living on our shoes live much longer and 90-95% of microbes are transferred to tile floors from shoes.
While disinfectant chemicals such as bleach and peroxide will disinfect floors, they may also be harmful additions to the problem. UVC energy, emitted by Clean Air’s UV-FLOOR, perform an essential function in the sanitization and disinfection of microbial dangers contained on the floor surface.
EFFICIENT STERILIZATION:
ultraviolet rays can kill bacteria, viruses, allergens, molds more effectively. Ultraviolet radiation can remove odors and can remove 99.999% of bacteria such as fungi, dust mites, viruses, etc.
Peak Wavelength: 270 to 280nm |
Powered by germicidal UVC LED, it sanitizes every the Floor in just 2 seconds. |
Provided with sensor - auto off if turned towards body |
Power Rating 20W/ 40W |
In-Built dust absorber (Optional) |
![]() |
MODEL | UV DOSE REQUIRED | UV-FLOOR-40 | UV-FLOOR-80 |
---|---|---|---|
uW/cm2 | 99.999% Kill Time (Seconds) | 99.999% Kill Time (Seconds) | |
BACTERIA | |||
Staphylococcus Aureus (MRSA) | 6600 | 0.05 | 0.10 |
Legionella Pneumophilia | 12300 | 0.10 | 0.19 |
Escherichia Coli | 6600 | 0.05 | 0.10 |
Salmonella Enteritidis | 7600 | 0.06 | 0.12 |
Mycobacterium Tuberculosis | 10000 | 0.08 | 0.16 |
Costridium Difficile C-Diff) | 24000 | 0.19 | 0.38 |
Pseudomonas Aeruginosa | 5500 | 0.05 | 0.10 |
VIRUSES | |||
Influenza | 6600 | 0.05 | 0.10 |
Infectious Hepatitis | 8000 | 0.06 | 0.13 |
Bacteriophage | 6600 | 0.05 | 0.10 |
Rotavirus / Norovirus | 24000 | 0.19 | 0.38 |
MOLD | |||
Aspergillus Flavus | 99000 | 0.79 | 1.55 |
UVC energy supplied by the LOKOZO contained within our Floor Sanitising System has the ability to prevent biological growth. UVC is capable of breaking molecular bonds, which disrupts the cellular growth of any target organism. UVC alters the DNA of the organism, preventing reproduction and multiplication.
The key to UVGI is to apply a chronic dose of Ultraviolet energy that kills 99.999% of the target organism. The UVC output of our UV-FLOOR Floor Sanitisation Systems has been enhanced by the inclusion of special reflective materials engineered into the design, which magnify the UVC energy levels and reduce the time required to provide the fatal dose of UVC to the contaminated floor surface.
The table on the left relates specifically to the two Floor Sanitiser Systems, UV-FLOOR-40 and UV- FLOOR-80. For example; using the UV-FLOOR- 80, the kill rate for MRSA is only 0.06 seconds. This means that system operatives can push the system at standard walking speed to guarantee effective pathogen control.
FEATURES | UV-FLOOR-40W | UV-FLOOR-80W |
---|---|---|
EFFECTIVEOPERATION WIDTH | 450mm | 900mm |
TOTAL WEIGHT | 7.5kg | 11.5kg |
UVC POWEROUTPUT | 3,100µW-s/cm² | 6,200µW-s/cm² |
VOLTAGE | 90 to 270VAC50 to 60 Hz | 90 to270VAC50 to 60 Hz |
POWER RATING | 40W | 80W |
CONSTRUCTION | SS 304 | SS 304 |
LIFE OF UVCLED | 40000hr | 40000hr |

CAUTION:
DO NOT USE this fixture with a dimming circuit; however, it can be used with a switched outlet. Per the National Electric Code (NEC), switched wall outlets cannot be used with wall dimmers.
LOWER MAINTENANCE COSTS:
40,000 hours rated life time, lasts up to 36 years (3 hours per day).